Mutlu, SerhatGüler, OlcayUçar, Adem KalyoncuMahiroğulları, Mahir10.07.20192019-07-1010.07.20192019-07-102014Mutlu, S., Güler, O., Uçar, A. K. ve Mahiroğulları, M. (2014). An unusual complication following total hip arthroplasty: median circumflex femoral artery pseudoaneurysm. Acta Orthopaedica et Traumatologica Turcica, 48(1), 106-108. https://dx.doi.org/10.3944/AOTT.2014.30001017-995Xhttps://hdl.handle.net/20.500.12511/1416https://dx.doi.org/10.3944/AOTT.2014.3000We report a case of a pseudoaneurysm of the medial circumflex femoral artery that presented 4 months following cementless left total hip arthroplasty (THA). A successful embolization was achieved using super-selective catheterization and coil embolization. Arterial complications associated with THA are remarkably rare. Endovascular techniques have been shown to be effective and are considered a valid alternative to conventional surgery.eninfo:eu-repo/semantics/openAccessAneurysmCoil EmbolizationFemoral ArteryTotal Hip ReplacementVascular ComplicationAn unusual complication following total hip arthroplasty: median circumflex femoral artery pseudoaneurysmArticle48110610810.3944/AOTT.2014.3000Q4Q2