Basit öğe kaydını göster

dc.contributor.authorToptan, Hande
dc.contributor.authorAğel, Esra
dc.contributor.authorSağcan, Hasan
dc.contributor.authorErtunç, Yiğit M.
dc.contributor.authorElmas, Bahri
dc.contributor.authorKöroğlu, Mehmet
dc.contributor.authorŞengil, Ahmet Zeki
dc.contributor.authorAltındiş, Mustafa
dc.date.accessioned2022-09-05T13:29:19Z
dc.date.available2022-09-05T13:29:19Z
dc.date.issued2022en_US
dc.identifier.citationToptan, H., Ağel, E., Sağcan, H., Ertunç, Y., Elmas, B., Köroğlu, M. ... Altındiş, M. (2022). Rapid molecular diagnosis of group a streptococcus with a novel loop mediated isothermal amplification method. Clinical Laboratory, 68(8), 1589-1595. http://doi.org/10.7754/Clin.Lab.2021.210925en_US
dc.identifier.issn1433-6510
dc.identifier.urihttp://doi.org/10.7754/Clin.Lab.2021.210925
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9693
dc.description.abstractBackground: Group A Streptococcus (GAS) is the most common bacterial cause of acute tonsillopharyngitis. In this study, it was aimed to evaluate the performance of a novel Loop Mediated Isothermal Amplification (LAMP) method in the rapid diagnosis of GAS in samples taken from children with a pre-diagnosis of acute bacterial tonsillopharyngitis by comparing it with culture and rapid antigen test (RAT) methods. Methods: A total of 100 throat swab samples taken from children at the pediatrics outpatient clinic with suspected tonsillopharyngitis were included in the study. Throat swab samples were analyzed by RAT, throat culture, and LAMP method. GAS suspected colonies were identified with MALDI-TOF MS system. The isothermal amplification reaction for LAMP was conducted by a novel LAMP instrument. Results: According to the results of throat cultures; 53 of them were positive and 47 were negative in terms of GAS. Six (11.32%) of the culture positive samples were found to be negative by the RAT (sensitivity; 88.68%, specificity 100%). While the antigen test was positive, no culture negative sample was detected. One of the culture positive samples was found negative by LAMP. In two samples, while throat culture was negative, it was observed that LAMP was positive (sensitivity; 98.11%, specificity; 95.74%). In one of these samples, the bacteria grown in the culture were identified as Streptococcus dysgalactiae by mass spectrophotometry. Conclusions: In this study, it was determined that the LAMP method used in the diagnosis of throat infections caused by GAS has high sensitivity and specificity. We believe that the instrument is easy to use, low cost, portable, and adaptable to point of care tests. There are very few studies in the literature regarding the use of the instrument in this field, and it should be evaluated in terms of its usability in daily practice with new studies.en_US
dc.language.isoengen_US
dc.publisherVerlag Klinisches Labor GmbHen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBacte-Rial Tonsillopharyngitisen_US
dc.subjectGroup A Streptococcusen_US
dc.subjectRapid Antigen Testen_US
dc.subjectStreptococcus Pyogenesen_US
dc.subjectThroat Cultureen_US
dc.titleRapid molecular diagnosis of group a streptococcus with a novel loop mediated isothermal amplification methoden_US
dc.typearticleen_US
dc.relation.ispartofClinical Laboratoryen_US
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Laboratuvar Teknikleri Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Tıbbi Mikrobiyoloji Ana Bilim Dalıen_US
dc.authorid0000-0001-6522-9648en_US
dc.identifier.volume68en_US
dc.identifier.issue8en_US
dc.identifier.startpage1589en_US
dc.identifier.endpage1595en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doihttp://doi.org/10.7754/Clin.Lab.2021.210925en_US
dc.institutionauthorSağcan, Hasan
dc.institutionauthorŞengil, Ahmet Zeki
dc.identifier.wosqualityQ4en_US
dc.identifier.wos000835266800001en_US
dc.identifier.scopus2-s2.0-85135911721en_US
dc.identifier.pmid35975490en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster