Basit öğe kaydını göster

dc.contributor.authorÇağlar, Mustafa
dc.contributor.authorKayacık, Hande
dc.contributor.authorKarabul, Yaşar
dc.contributor.authorKılıç, Mehmet
dc.contributor.authorGüven Özdemir, Zeynep
dc.contributor.authorİçelli, Orhan
dc.date.accessioned2019-12-19T14:13:04Z
dc.date.available2019-12-19T14:13:04Z
dc.date.issued2019en_US
dc.identifier.citationÇağlar, M., Kayacık, H., Karabul, Y., Kılıç, M., Güven Özdemir, Z. ve İçelli, O. (2019). Na2Si3O7/BaO composites for the gamma-ray shielding in medical applications: Experimental, MCNP5, and WinXCom studies. Progress in Nuclear Energy, 117. https://doi.org/10.1016/j.pnucene.2019.103119en_US
dc.identifier.issn0149-1970
dc.identifier.urihttps://doi.org/10.1016/j.pnucene.2019.103119
dc.identifier.urihttps://hdl.handle.net/20.500.12511/4565
dc.description.abstractThe role of BaO in the glassy structured Na2Si3O7 was investigated in the context of gamma radiations shielding parameters in the study. The mass attenuation coefficient, half layer value, and mean free path of the Na2Si3O7/BaO composites were calculated experimentally for the photons with the energies of 81 keV and 356 key emitted from 133Ba point radioactive source. The same parameters were also calculated by Monte Carlo N-particle simulation (MCNP5) for the gamma photons which are emitted from Ba-133, (241)AM (TC)-T-99m, (LU)-L-177, Ir-192, and Cs-137 radioactive sources. The effective atomic number and effective electron density were determined by WinXCom software. Additionally, the scattered gamma photon intensity of the composites was realized for the energy of 364 key and compared with the most utilized radiation shielding material lead. It was concluded that the composite having the highest BaO additive exhibits the best gamma photon absorption ability at all energies investigated.en_US
dc.description.sponsorshipYildiz Technical Universityen_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectSodium Silicateen_US
dc.subjectBarium Oxideen_US
dc.subjectCompositeen_US
dc.subjectGamma-Ray Shieldingen_US
dc.subjectMCNPen_US
dc.subjectWinXComen_US
dc.titleNa2Si3O7/BaO composites for the gamma-ray shielding in medical applications: Experimental, MCNP5, and WinXCom studiesen_US
dc.typearticleen_US
dc.relation.ispartofProgress in Nuclear Energyen_US
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Görüntüleme Teknikleri Ana Bilim Dalıen_US
dc.authorid0000-0002-0103-7683en_US
dc.identifier.volume117en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.pnucene.2019.103119en_US
dc.identifier.wosqualityQ1en_US
dc.identifier.scopusqualityQ1en_US