dc.contributor.authorAkyol, Ali
dc.contributor.authorBaykal, Doruk
dc.contributor.authorAkdağ, Akın
dc.contributor.authorŞensoy, Özge
dc.contributor.authorSon, Cağdaş Devrim
dc.date.accessioned2022-09-16T11:18:00Z
dc.date.available2022-09-16T11:18:00Z
dc.date.issued2023en_US
dc.identifier.citationAkyol, A., Baykal, D., Akdağ, A., Şensoy, Ö. ve Son, C. D. (2023). A new ratio-metric pH probe, "ThiAKS Green" for live-cell pH measurements. Photonic Sensors, 13(1). https://doi.org/10.1007/s13320-022-0666-5en_US
dc.identifier.issn1674-9251
dc.identifier.issn2190-7439
dc.identifier.urihttps://doi.org/10.1007/s13320-022-0666-5
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9725
dc.description.abstractDeviation of the H+ concentration from optimum values within the organelles is closely associated with irregular cellular functions that cause the onset of various diseases. Therefore, determining subcellular pH values in live cells and tissues is valuable for diagnostic purposes. In this study, we report a novel ratiometric fluorescence probe 1H-pyrazole-3-carboxylic acid, 4-(benzo[d]thiazol-2-yl)-3-(2,4-dihydroxy-3-methylphenyl)-1H-pyrazole-5-carboxylicacid4-(2-benz othiazolyl)-5-(2,4-dihydroxy-3-methylphenyl), to which we will refer as ThiAKS Green (Thiazole AKyol shifting green), that is pH sensitive. The results presented here show that the probe can penetrate the cell membrane in less than 30 minutes and does not show any detectable toxicity. The measured color shifts up on pH change are linear and most significant around physiological pH (pKa=7.45), thus making this probe suitable for live-cell imaging and intracellular pH measurements. During the long-incubation periods following the application of the probe and the fluorescent microscopy measurements, it shows stable properties and is easy to detect in live cells. In conclusion, the results suggest that ThiAKS Green can be used to obtain precise information on the H+ distribution at various compartments of the live cells.en_US
dc.description.sponsorshipGolgien_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectFluorescent Probeen_US
dc.subjectRatiometric Sensoren_US
dc.subjectIntracellular pHen_US
dc.subjectCell Imagingen_US
dc.subjectFluorescent Microscopyen_US
dc.titleA new ratio-metric pH probe, "ThiAKS Green" for live-cell pH measurementsen_US
dc.typearticleen_US
dc.relation.ispartofPhotonic Sensorsen_US
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Bilgisayar Mühendisliği Bölümüen_US
dc.authorid0000-0001-5950-3436en_US
dc.identifier.volume13en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s13320-022-0666-5en_US
dc.institutionauthorŞensoy, Özge
dc.identifier.wosqualityQ2en_US
dc.identifier.wos000849457800001en_US
dc.identifier.scopus2-s2.0-85137544749en_US


Bu öğenin dosyaları: