Basit öğe kaydını göster

dc.contributor.authorKulaç, Selman
dc.contributor.authorArslan, Hüseyin
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:37:59Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:37:59Z
dc.date.issued2016en_US
dc.identifier.citationKulaç, S. ve Arslan, H. (2016). Reliable listen-before-talk mechanism for medical implant communication systems. 18th IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) içinde (636-639. ss.). Munich: Germany, September 14-17, 2016. https://dx.doi.org/10.1109/HealthCom.2016.7749531en_US
dc.identifier.isbn9781509033706
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1513
dc.identifier.urihttps://dx.doi.org/10.1109/HealthCom.2016.7749531
dc.description.abstractHealth care applications of wireless communication have been finding places dramatically. One of these applications is communication of implantable medical devices (IMD)s. It is expected that the number of IMDs will increase greatly in the near future. As a result, significant congestion will be experienced in medical implant communication service (MICS) band, leading to interference problems. In this study, we propose reliable listen-before-talk (LBT) mechanism at low signal-to-noise ratios (SNR)s for medical implant communication systems in order to mitigate the interference effects. In our method, we have just brought out power difference between mean peak and mean lowest power spectral values and it provides reliable and simple monitoring of MICS channels' occupation fastly. Our proposed method has superior performance when threshold power level is considered according to the federal communication commission (FCC) Part 95 regulatory standard.en_US
dc.language.isoengen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectAdaptive Frequency Agilityen_US
dc.subjectIMD Programmeren_US
dc.subjectListen Before Talken_US
dc.subjectMetAids Banden_US
dc.subjectMICS Banden_US
dc.subjectWireless IMD Communicationsen_US
dc.titleReliable listen-before-talk mechanism for medical implant communication systemsen_US
dc.typeconferenceObjecten_US
dc.relation.ispartof18th IEEE International Conference on e-Health Networking, Applications and Services (Healthcom)en_US
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümüen_US
dc.authorid0000-0001-9474-7372en_US
dc.identifier.startpage639en_US
dc.identifier.endpage636en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1109/HealthCom.2016.7749531en_US